Pacemaker : 2017.000.076
Cardiovascular : Painting a picture of the many developments ocurring in the field of cardiology
Object ID Number:
2017.000.076
Object Name:
Pacemaker
Type:
Multi–Programmable Pacemakers
Manufacturer:
Medtronic, Inc. and Intermedics, Inc.
Manufactured from:
1990
Manufactured to:
2000
Description / History:
Medtronic Minix SSI Multi–Programmable Pacemaker, Intermedics Nova II Pacemaker c.1990s

These pacemakers offered advanced programmability and contained more advanced (and smaller) circuitry than their earlier counterparts.
Dimensions:
H–2 W–1.75 D–0.25 inches
Additional Information:
Pacemakers–devices which control abnormal heart rhythms by the emission of electrical pulses which prompt the heart to beat at a normal rate–have been around since the late 1950's.

The earliest pacemakers were large, bulky devices which were attached to the outside of a person's chest, and contacted the heart with permanent wires inserted through the skin and attached to the surface of the heart.

By 1958, physicians in Sweden had succeeded in implanting the entire pacemaking device inside a patient's chest. Their first patient, a 40 year old man, was given a pacemaker whose battery failed in a few hours. The next pacemaker he was given lasted a few weeks, yet he was able to survive and receive yet another pacemaker in 1960, and he lived for 40 more years (and received 26 pacemakers in his lifetime).

The earliest pacemakers implanted were ungainly devices, powered by large zinc–mercury oxide batteries, delivered stimuli to the heart at a preset rate, regardless of the changing needs of the patient (whether the patient was running a marathon or asleep, the pacemaker ran at the same rate), and continued to deliver stimuli even when the patient's heart was working normally (a dangerous occurrence which could lead to heart failure).
In the late 1960's, however, physicians began developing pacemakers which were deactivated when the patient's heart was running normally. These pacemakers, known as ventricular inhibited (VVI) or ventricular triggered (VVT) were the dominant model from the mid–1960's to the early 1980's. In this exhibit, we have multiple pacemakers which function in this manner.

In the 1970's, the major developments in the pacemaker field included the introduction of lithium–based batteries (which allowed pacemakers to become markedly smaller), and the development of programmability. In the late 60's and early 70's pacemakers could have their rates adjusted only by surgical intervention. In 1972, however, pacemakers were introduced which could be manipulated without surgery, using just an external remote. These programmable pacemakers become almost universal by the 70's (note that most of the pacemakers in this exhibit are programmable), and are similar in this respect to modern pacemakers, which can be checked and manipulated over the phone, without a visit to the doctor.